Basic Electrical Safety Analyzer
A Basic Electrical Safety Analyzer designed to test all Non-ECG equipment.
The LKG 601, Electrical Safety
Analyzer is an extremely easy to use portable Electrical Safety
Analyzer designed specifically for testing non-ECG equipment. Ground
resistance, leakage current, and instrument current test measurements
are displayed on its large LCD.
With its unique operating features, the LKG 601,
Electrical Safety Analyzer out performs all other basic electrical
safety analyzers. To insure accuracy, each test has calibrated test
points. The accessible instrument fuse solves the maintenance problems
of built-in fuses. The selectable test load provides testing
flexibility.
For the routine electrical safety testing of all your electrical equipment, the LKG 601, Electrical Safety Analyzer is simply the best selection.
|
 |
 |
 |
Easy to use |
 |
Large LCD Display |
 |
Accessible Line Fuse |
 |
Calibrated Test Points |
 |
Selectable Test Loads |
 |
15 and 20 Amp Capability |
 |
Point-to-Point Testing |
 |
Use any Test Cable |
 |
Complies with both AAMI/ESI 1993 And IEC 601 |
 |
Complies with AAMI/ESI 1993 |
 |
LED Unit of Measure Indicator |
 |
 |
Line Voltage |
 |
Cord Resistance |
 |
Case Leakage Current |
 |
Earth Leakage Current |
 |
Instrument Current |
 |
Point-to-Point Measurement |

|
|
Leakage Current
0-1999
micro amps. All Current measurements are made through the AAMI/ANSI ESI
- 1985 or IEC 601 - 1 test load. The meter readings correspond to the
true RMS value of the current.
Accuracy
±1% of reading, ±1 LSD DC to 1 kHz,
±2.5% of reading, ±1 LSD 1 kHz to 100 kHz,
±5% of reading, ±1 LSD 100 kHz to 1 mHz.
Resistance
0 to 1999 milli ohms.
Accuracy is ±1% of reading, ±1 LSD
Device Current
0 to 19.99 amps.
Accuracy is ±2% of FS, ±1LSD
Measures
Ground Resistance, Internal and External Leakage Current, and Instrument Current.
Test Receptacle
Hospital
Grade 110V AC - 15 amp or 220V AC 10 amp. The rocker polarity switch
selects NORMAL, OFF and REVERSE Polarity to the test receptacle, and a
momentary Neutral switch will open the neutral line to the test
receptacle.
|
Display |
: |
3½ Digit LCD Display |
Power Requirements |
: |
110V AC 50 - 60 Hz, 15 amps
220V AC, 50 - 60 Hz, 10 amps
|
Physical Dimensions |
: |
5.5 x 3.25 x 2.5 inches
(13.75 x 8.13 x 6.25 cms) |
Weight |
|
1 lbs (0.45 kg) |
Ambient Temperature
Operating Range |
: |
59° to 95° F (15° to 40° C) |
Storage Temperature |
: |
0° to 122° F (-20° to 60° C) |
Relative Humidity |
: |
90% (max) at temperatures |
|
|
 |